Z-shaped steel

Z-shaped steel is made from hot-rolled or galvanized steel sheet/strip, formed by multiple roll forming processes and then cut to length. Its cross-section resembles the letter “Z,” with flanges extending in opposite directions and inwardly rolled edges at the ends. This unique geometry allows adjacent purlins to be nested and overlapped at supports, forming a continuous beam load-bearing system, making it a preferred profile for large-span, steep-slope roofs. The product conforms to GB/T 6728-2025 “Cold-formed Steel Sections for Structural Use” and can be designed and supplied according to international standards such as EN 1993-1-3, AISI S100, and AS/NZS 4600.

Material and Surface Treatment

Standard / System Common Grades Yield Strength (Reference)
China GB Q235B, Q355B (low-alloy high-strength steel) ≥235 / ≥355 MPa
USA ASTM A36, A572 Gr.50, A653 (galvanized sheet) ≥250 / ≥345 / ≥350 MPa
Europe EN S235JR, S355JR; galvanized sheet S350GD, S450GD (EN 10346) ≥235 / ≥355 / ≥350 / ≥450 MPa
Australia AS/NZS G450 and other cold-formed structural steel grades ≥450 MPa
Japan JIS SS400, SS490 (JIS G3101) ≥245 / ≥295 MPa

Surface Treatment: Options include bare steel oiling, continuous hot-dip galvanizing (Z100/Z180/Z275, double-sided 100–275 g/m²), aluminized zinc plating (AZ150, superior corrosion resistance at cut edges), post-forming hot-dip galvanizing (G90 / zinc layer up to 400–600 g/m²), and spraying. For coastal, high-humidity, or corrosive environments, it is recommended to increase the zinc layer weight.

Z-shaped steel

Structural Features

The cross-section consists of a web (Web, H), two opposing flanges (Flange, B/b), an inwardly rolled edge (Lip, C), and a wall thickness (t). Corners have a radius of radius R. Specifications are marked as Z H×B×C×t, for example, Z160×60×20×2.5.

  • The flanges can extend at right angles or slightly at an angle in opposite directions, often with a slight difference in width between the two flanges, facilitating nested overlapping;
  • After overlapping, the sections overlap at the point of maximum bending moment at the support, forming a continuous beam along the entire purlin, reducing mid-span bending moment and deflection;
  • Rolled edges improve the local buckling capacity of the flanges, resulting in good stability for thin-walled sections;
  • The profiles can be nested and packaged, maximizing transport space utilization.

Product Parameters

Parameter Common Range
Web depth, H 80–350 mm (commonly 100–300 mm)
Flange width, B 40–100 mm (commonly 50–80 mm)
Lip width, C 10–30 mm (commonly 15–25 mm)
Thickness, t 1.0–5.0 mm (commonly 1.5–3.0 mm)
Cut-to-length 6–12 m, customizable
Lap length Typically 600–1000 mm, determined by span and load calculation
Dimensional tolerance Web depth ±0.5–2.0 mm; flange ±1–2 mm; thickness ±0.05–0.25 mm (per agreed standard)
Mechanical properties Q235B: yield ≥235 MPa, tensile 370–500 MPa, elongation ≥26%; Q355B: yield ≥355 MPa
Applicable span Approx. 2.5–8 m; up to approx. 9 m in multi-span lapped continuous systems (subject to structural calculation)

Common Model Reference

Model Web Depth H (mm) Flange Width B (mm) Lip C (mm)
Z100×50×20 100 50 20
Z120×50×20 120 50 20
Z140×50×20 140 50 20
Z160×60×20 160 60 20
Z180×70×20 180 70 20
Z200×70×20 200 70 20
Z220×75×20 220 75 20
Z250×80×20 250 80 20
Z300×80×20 300 80 20

Notation: H = web depth, B = flange width, C = lip width, t = wall thickness; designation format is Z H×B×C×t (mm), e.g. Z160×60×20×2.5.

Z-shaped steel

Product Features

1. Continuous Load-Bearing Capacity and High Efficiency: Nested overlapping at the supports forms a continuous beam, significantly improving overall load-bearing capacity and stiffness compared to simply supported arrangements under the same steel usage conditions; the single-section modulus is similar to that of C-shaped steel of the same specification, with the advantage stemming from the system’s continuity.

2. Suitable for Large Spans and Slopes: Significantly improved load-bearing efficiency for roofs with slopes of approximately 5% or more (especially above 10°), suitable for spans of 6 m or more.

3. Steel Savings: Compared to traditional channel steel and angle steel, the weight is reduced by approximately 15%–20%. In multi-span roofs, it can reduce steel consumption compared to a simply supported C-type scheme, lowering the load on the main structure and foundation.

4. Factory Prefabrication and Quick Installation: CNC pre-punching and length cutting are possible, with on-site bolt assembly eliminating the need for extensive welding.

5. Corrosion Resistance and Durability: Galvanized/aluminized zinc products have a service life of 15–30 years in normal environments, resulting in low maintenance costs.

6. Transportation and Recycling Advantages: Profiles can be stacked and packaged to save on shipping costs; the steel is 100% recyclable, meeting green building requirements.

Application Areas

  • Industrial and Logistics Buildings: Roof purlins for large-span steel structure factories, logistics warehouses, and cold storage facilities.
  • Heavy-Load and Complex Roofs: Roof supports for roofs with high snow loads, strong wind suction, and those requiring future photovoltaic installations.
  • Pitched Roof Buildings: Portal frame factories, pitched roof warehouses, and enclosure systems for large markets and sports stadiums. New Energy: Photovoltaic carports, rooftop photovoltaic support rails and purlins.
  • Others: Agricultural greenhouses and poultry houses, prefabricated public buildings, long wall beams (girts), lightweight trusses and curtain wall auxiliary supports.

Z-shaped steel installation

Selection and Ordering Tips

  • Structural calculations based on dead load, snow load, and wind load are required to determine the model and wall thickness.
  • For roofs with a large slope or spans exceeding 6 m, Z-type is preferred; C-type can be used for walls and smaller spans.
  • Overlap length, overlap position, and bolt hole spacing should be prefabricated in the factory according to design requirements.
  • Pay attention to the installation direction (flange orientation and overlap sequence) to avoid eccentric stress.
  • For heavy-load, seismic, or large-span projects, Q355B or high-strength galvanized steel is recommended.
  • For corrosive environments, the zinc layer weight and anti-corrosion process should be clearly defined, and material certificates and coating test reports should be obtained.